On Thursday 29 April 2004 01:10, user86 wrote:
On Wednesday 28 April 2004 12:55, user86 wrote:
There are two workarounds:
1. Enable the router's firewall in its "Advanced Setup"
2. Forward port 1900 of the router to a non-existent internal IP address
(such as 192.168.2.248 if it isn't in use).
A third workaround on the 7008ABR with firmware 1.032 is to go into the
router's "Advanced Setup" click "System" then "Remote Management" and click
"Apply" (even without changing any setting) and port 1900 then closes
itself.
Ugh! Scratch that third workaround! I just found out that that third
workaround only works as long as the router stays up. If the router is
rebooted for *any* reason, such as during a power outage or by the user
through the web interface, port 1900 is open again when the router boots back
up!