nanog mailing list archives

Re: Pad 1310nm cross-connects?


From: Måns Nilsson <mansaxel () besserwisser org>
Date: Sun, 20 Oct 2013 21:59:04 +0200

Subject: Re: Pad 1310nm cross-connects? Date: Sun, Oct 20, 2013 at 07:21:42AM +0200 Quoting Måns Nilsson (mansaxel () 
besserwisser org):
Subject: Pad 1310nm cross-connects? Date: Sat, Oct 19, 2013 at 07:33:19PM -0700 Quoting Chris Costa (ccosta92630 () 
gmail com):
What are the opinions/views on attenuating short, 1310nm LR cross-connects.
 Assume < 20m cable length and utilizing the same vendor optics on each
side of the link.  Considering the LR transmit spec doesn't exceed the
receiver's high threshold value do you pad the receiver closer to the
median RX range to avoid potential receiver burnout over time, or just
leave it un-padded?

      LR usually needs padding in that scenario, IMHO. This also 

My apologies. I was thinking not of 10km / 20km class optics but the
80-100km stuff. There, padding is quite necessary in short-range setups.
For 10/20km stuff, I, too, have run lots of 2m patch cords directly
between linecards without harm.

-- 
Måns Nilsson     primary/secondary/besserwisser/machina
MN-1334-RIPE                             +46 705 989668
One FISHWICH coming up!!

Courtesy conversions: (km->miles, km-> miles, metres/100 -> feet) 

10/1.6
6.25000000000000000000
80/1.6
50.00000000000000000000
200/(2.54*12)
6.56167979002624671916


Attachment: signature.asc
Description: Digital signature


Current thread: