[NANOG] Re: Small Capacity UPS


From: Javier J via NANOG <nanog () lists nanog org>
Date: Thu, 10 Apr 2025 16:35:10 -0400

I agree. The cheap solar batteries in my shed have gone down to the point
the BMS turned them off. So I added a second solar panel, then I added 3
more batteries in parallel. I just recently (with the help of my
landscapers awesome shovel) moved the panels to a more optimal location and
buried the DC cable to the shed. Now I never get lower than 70% SOC. I'm at
100% by 1pm on sunny days. It's a test off-grid system to power poe cams,
smart bulbs, watch what wild animals try to eat my chickens etc. But really
it is to see what location is best because I won't be cutting down trees I
don't own, or don't want to.

Going strong since 2013.

Some of these batteries now have bluetooth, I added a bluetooth module on
mine.
BMS protects the cells, keeps them balanced etc, just to add to that.

I couldn't find the video but Will Prowse on youtube has a solar powered
gate opener operating for years, battery exposed to the elements in las
vegas, going strong after years. I don't think I will ever buy a lead acid
based battery again.



On Thu, Apr 10, 2025 at 1:13 AM Mark Tinka via NANOG <nanog () lists nanog org>
wrote:



On 4/9/25 14:27, Gary Sparkes wrote:
Long term storage, of course, is different, but that's a much easier
solved problem, and design specs are often in the -30c to 25c range for
optimal capacity retention over long term storage. But operationally,
25-50c is perfectly fine. Past ... above 5c, I think, you're looking at a
10% capacity fluctuation in that 5c to 50c range.

Yes, most LFP batteries will work even at 60°C, but that does not mean
you should do it if you want to get the most out of your investment.

The biggest issue is battery aging, and keeping it within recommended
temperature values will ensure they last longer than if you don't.


While true, heat is the enemy of lithium batteries of any type, deep
discharging is the second worst enemy (BMS prevents actual cell damaging
deep discharge, but you really should never go below 30% of rated capacity
if you can ever help it - this is the most stressful zone), then charging
too rapidly - too high rate of charge.

The point of the BMS is to prevent you from operating your battery in
dangerous territory.

30% is not a reasonable floor to stop discharging a Li-Ion battery. All
you are doing there is limiting your available capacity. The recommended
floor to stick to is 20%. However, it is perfectly fine to go as low as
10% without any appreciable loss of overall capacity. And in an
emergency, you can even go to 5% and still maintain good long term
capacity.

This is where Li-Ion outshines LA by a mile.

Limiting your capacity by not discharging to, at least, 20% SoC, is
quite pointless based on all the information we have so far, because
calendar aging is still going to get you either way.

Mark.
_______________________________________________
NANOG mailing list

https://lists.nanog.org/archives/list/nanog () lists nanog org/message/5UTUKUX4AWGUFY3LILDBEQGLTEBTOK64/
_______________________________________________
NANOG mailing list 
https://lists.nanog.org/archives/list/nanog () lists nanog org/message/6VWZ7P6WVWTIFZ64P6BJZLZWZY5PFVD7/

Current thread: