nanog mailing list archives

Re: Last-resort tunnel recommendations on WAN network ...


From: Michael Greenup via NANOG <nanog () lists nanog org>
Date: Thu, 12 Mar 2026 19:28:04 -0000

Hi Bryan!

Just wondering if you could be over complicating things. One option is to continue to manage your devices in-band with 
your current strategy and if that fails, switch to an out-of-band solution. This way, the box is still reachable no 
matter what happens short of a complete power outage or worse.

One option to do this is with Opengear hardware (https://opengear.com/) and using their Lighthouse software 
(https://opengear.com/products/lighthouse/) to manage it back at HQ. There are other options out there as well but this 
could be cheaper than buying a new server for wireguard (also a viable option) or a full-on networking device.

Of course, there might be other considerations given your statement "management and whatnot" but if all you are 
concerned about is contacting the box when a line goes down, this is might be a good option for your use case.

Regards,

Michael

The views and opinions included in this email belong to the author and are not representative of the views and opinions 
of the company which employs me. If you find a spelling or grammatical error, you may keep it.