nanog mailing list archives

Re: Hardware question


From: Kevin Shymkiw via NANOG <nanog () lists nanog org>
Date: Mon, 23 Jun 2025 09:52:50 -0600

Thanks for the info there, I hadn't seen OPS's when I was looking.  My
almost workaround was a 50:50 optical tap, but without backup power it
seemed to only complicate the solution for such a minor gain

On Mon, Jun 23, 2025 at 9:50 AM Mark Tinka <mark@tinka.africa> wrote:



On 6/23/25 17:40, Kevin Shymkiw via NANOG wrote:

- Only available in Copper. - You can't FTW optical since you need an OEO
conversion


An OPS (optical protection switch) can continue to pass light in the event
of power failure. The only issue is the last state gets locked in, so there
won't be any failover in case the worker path dies, as that requires power.

Mark.